Page 21 - My FlipBook
P. 21
oclave – Industry Grade, Lab Scale and Desktop

To cater to the thermoplastic ¡¡ P C, PLC, Front –end controllers and
composites processing require- Recorder based C&I architecture
ments, an high temperature (425
deg C and high pressure (15Barg) ¡¡ M ultiple level safeties
Autoclave is developed. Presently, ¡¡ Heater power steering logic
one such autoclave is being supplied ¡¡ Advanced insulation system for
to IIT Delhi.
minimal energy losses
The technology has been ¡¡ I dentification and management of
transferred to several MSMEs in
the country. These industries have single point failures
generated a revenue of about 40 ¡¡ Advanced process control software
crores as on date.
with remote monitoring
Year of Development : 2010 ¡¡ M aster and stand by computer

Applications control

¡¡ Manufacture of composite struc- Level/Scale of Development : TRL-9
tures for strategic aerospace, Successfully commercialized.
automobile, education and allied
sectors Intellectural Property Rights (IPR):
Patent under process
Salient Technical Features
Major Plant Equipment and
¡¡ Fail safe and easy to operate Machinery Required
¡¡ A uto, semi-auto and manual
Heavy engineering fabrication facility
modes of operation
¡¡ D avit arm/ Hinged door with lock Market potential

ring less design ¡¡ Desktop autoclave for acdemia :
¡¡ P ressurised motor with health 100-120 systems over a time pe-
riod of 10-12 years.
monitoring
¡¡ Industry Grade and Lab Scale
autoclave is about Rs.100 cr for
Indian market and Rs.100 cr for
export market in the next 5-6 years.